FallNet Pro: Wearable AI Healthcare Sentinel
Dual-Form Wearable AI IoT System (Watch & Pendant) and Clinical Telecare Fleet Station developed to protect elderly individuals and hospital patients through deterministic kinematic physics and automated cloud dispatch.
Why Traditional Panic Buttons Fail in Geriatric Falls
Geriatric falls represent the #1 cause of fatal and non-fatal injuries in seniors over 65. The life-safety bottleneck lies in human unconsciousness.
Standard emergency necklaces and bracelets require the fallen resident to consciously press an SOS button. Real-world hospital studies prove that in over 78% of serious geriatric falls, the patient is completely incapable of pressing the button due to:
FallNet Pro eliminates manual panic buttons by combining continuous edge computing with automated cloud telecare:
Dual Wearable Form Factors: Watch & Pendant Modules
Both hardware form factors share an identical 50Hz edge IMU kinematic engine, secure Wi-Fi stack, and cloud telecare protocol.
Clinical Target Population: Active ambulatory elderly, rehabilitation outpatients, and independent care residents.
- Display Subsystem: 2.06-inch High-Definition AMOLED ($410 \times 502$ px, 336 PPI, CO5300 QSPI controller) with true-black contrast.
- Capacitive Touch: FocalTech FT3168 controller with gesture swipe and "I'M OK" button de-escalation.
- Acoustic Guidance: Onboard Everest ES8311 DAC + Class-D Power Amplifier micro-speaker (up to 85 dB SPL).
- Power & Fuel Gauge: AXP2101 PMIC with precision Coulomb-counting battery gauge.
Clinical Target Population: Frail residents, bedridden patients, and individuals who find wristwatches restrictive during sleep.
- Display Subsystem: 1.85-inch Circular Round LCD ($360 \times 360$ px, Sitronix ST77916 QSPI controller) with 20kHz PWM backlight.
- Ergonomic Chassis: Protective circular aluminum perimeter bezel with anti-allergic woven lanyard cord.
- Touch & Low-Power: Hynitron CST816S self-capacitive touch with ultra-low $1.5\,\mu\text{A}$ sleep standby mode.
- Power & Fuel Gauge: Texas Instruments BQ27220 precision Coulomb-counting fuel gauge (0x55 on I2C).
FallNet Pro Watch: Hardware Subsystem & Master Pinout
High-density multi-processor computing, Quad-SPI graphics, shared 400kHz I2C bus, and I2S digital audio codec.
โข Microprocessor: ESP32-S3 Dual-Core 32-bit Xtensa LX7 @ 240MHz with vector acceleration instructions for rapid 50Hz filter convolutions.
โข Memory Subsystem: 384KB ROM, 512KB SRAM, 8MB Octal PSRAM (high-res graphics buffer), and 32MB Quad/Octal SPI Flash.
โข Bus Topology: Dedicated QSPI Bus (GPIO 4-7, 11, 12) for AMOLED, Shared I2C Bus (GPIO 14, 15) for PMIC/RTC/Touch/Audio, and I2S Bus for speaker DAC.
| GPIO Pin | Signal Name | Target Subsystem | Functional Description |
|---|---|---|---|
| GPIO 0 | BOOT / KEY | System Key | Boot mode selection; tactile user navigation & "I'M OK" cancel key. |
| GPIO 4-7 | QSPI_SIO0-3 | CO5300 AMOLED | High-speed Quad-SPI pixel stream for true-black display. |
| GPIO 11, 12 | QSPI_SCL, CS | CO5300 AMOLED | High-speed pixel clock (up to 80 MHz) and active-low Chip Select. |
| GPIO 8, 13 | LCD_RESET, TE | CO5300 AMOLED | Display hardware reset and Tearing Effect frame synchronization. |
| GPIO 14, 15 | I2C_SCL, SDA | Shared I2C Bus | 400 kHz Fast-Mode bus connecting PMIC, RTC, Touch, IMU, and Audio. |
| GPIO 21 | IMU_INT | QMI8658 IMU | 50Hz motion threshold and tap wake-up hardware interrupt line. |
| GPIO 38, 39 | TP_INT, RTC_INT | Touch / RTC | Capacitive touch detect interrupt and PCF85063 real-time clock alarm. |
| GPIO 16, 41, 45 | I2S Clocks | ES8311 Audio | Master Clock (MCLK), Bit Clock (SCLK), Word Select (LRCK). |
| GPIO 42, 46 | I2S_DOUT, PA_CTRL | Audio Output | Digital audio serial data out to DAC and active-high speaker amplifier enable. |
| GPIO 1, 2, 3, 17 | MicroSD SPI | Card Socket | MOSI, SCK, MISO, and CS for offline continuous raw IMU flight recording. |
FallNet Pro Pendant: Hardware Subsystem & Master Pinout
Optimized circular display architecture, ultra-low-power CST816S touch, BQ27220 fuel gauge, and ES8311 audio.
โข Display Subsystem: 1.85-inch Circular Round LCD ($360 \times 360$ px) powered by Sitronix ST77916 Quad-SPI controller with hardware reset on GPIO 3.
โข Backlight Control: 20 kHz high-frequency PWM brightness control on GPIO 5 preventing audible coil whine.
โข Touch & Power: Hynitron CST816S capacitive touch (0x15) with 1.5ยตA sleep standby; TI BQ27220 fuel gauge (0x55); ES8311 DAC codec on GPIO 9 PA.
| GPIO Pin | Signal Name | Target Subsystem | Functional Description |
|---|---|---|---|
| GPIO 0 | BOOT / KEY | System Key | Boot mode selection; tactile user navigation & "I'M OK" cancel key. |
| GPIO 1, 4 | TOUCH_RST, INT | CST816S Touch | Hardware reset and low-active touch detection interrupt line. |
| GPIO 3, 5 | LCD_RST, BL | ST77916 LCD | Circular display hardware reset and 20kHz PWM backlight regulation. |
| GPIO 21, 40 | LCD_CS, SCLK | ST77916 LCD | Active-Low Chip Select and high-speed Quad-SPI pixel clock line. |
| GPIO 46, 45, 42, 41 | LCD_D0-D3 | ST77916 LCD | Quad-SPI high-throughput framebuffer data streaming lines. |
| GPIO 10, 11 | I2C_SCL, SDA | Shared I2C Bus | Primary 400kHz I2C bus connecting Touch, Audio Codec, Fuel Gauge, and IMU. |
| GPIO 6 | IMU_INT | QMI8658 IMU | Dedicated motion threshold and wake interrupt line. |
| GPIO 2, 48, 38 | I2S Clocks | ES8311 Audio | Master Clock (MCLK), Bit Clock (BCLK), and Frame Clock (LRCK). |
| GPIO 47, 9 | I2S_DOUT, PA_CTRL | Audio Output | Digital audio serial data out to DAC and active-high speaker amplifier enable. |
Wearable Human-Machine Interface: Dual Graphic Screens
Optimized true-black AMOLED graphics delivering sunlight readability, instant patient clinical feedback, and field provisioning.
1. Screen Header & RTC: "FALLNET PRO SENTINEL", synchronized 12-hour clock (12:28:27 PM) with blinking seconds, THU 24 SEP 2026.
2. Clinical Status Badge: STATUS: SAFE & ACTIVE during nominal activity, switching to amber VERIFYING (10s) or red CRITICAL SOS.
3. Twin Telemetry Grid: G-FORCE: 1.01G NORMAL (50Hz net vector) & BATTERY: 79% (4.01V Coulomb-counted fuel gauge).
4. Wi-Fi & RSSI: Active connected SSID with 4-bar RSSI ladder (Signal: 80% -60dBm).
5. Navigation Pill: "NETWORK > Tap or Click BOOT" (Screen transition or "I'M OK" cancel).
1. Local IP Badge: Displays the assigned IPv4 address on the hospital LAN (WIFI: 192.168.1.59).
2. SoftAP Provisioning Hotspot (Cyan): "START HOTSPOT / Broadcast AP" initializes an on-wrist Wi-Fi portal (192.168.4.1) for zero-wire credential setup without USB.
3. Cloud OTA Query (Blue): "CHECK UPDATE / Query Cloud Repo" queries cloud server to verify firmware SHA-256 checksums.
4. Return Navigation (Green): "< WATCH FACE / Return to Main Clock" immediately returns to clinical monitoring face.
Clinical Care Station: https://care.inayat.net/
Enterprise-grade, zero-install clinical operations dashboard connecting doctors, ward nurses, and remote caretakers.
Resident Status Orb: Dynamic circular indicator pulsing green (Normal/Safe), amber (Verifying 10s grace), or red (Critical SOS).
50Hz Real-Time Canvas: Continuous multi-point G-force stream ($0.0-4.5G$) displaying net acceleration vector, peak impact force ($G_{\text{peak}}$), and tri-axial gyro rates ($\omega_x, \omega_y, \omega_z$).
Live Telemetry Stream: Real-time bi-directional JSON console with auto-scroll, copy-to-clipboard, and quick action buttons (Beep, Siren, Mute, Test SOS).
Global Fleet KPI Cards: Instant totals for Monitored Residents (7), Online & Safe (1), Caretaker Review (0), and Critical SOS (0).
Dual-Wearable Device Cards: Displays patient cards for both Watch (2.06" AMOLED) and Pendant (1.85" LCD) units with live G-force, battery gauge, and room allocation.
Targeted Control Suite: Stream focus, per-device metadata Edit modal, individual OTA trigger, acoustic locator Beep, and SOS dispatch.
Screen 4: Fall Detection & Emergency SOS Timing
Bidirectional synchronization with wearable hardware and cloud databases, enabling clinical threshold calibration and audio level adjustments.
โข Two-Way Synchronization: Calibrates edge AI kinematic thresholds and escalation timing directly over MQTT topic fallnet/config/broadcast and persists to cloud PostgreSQL.
โข One-Click Presets: Pre-tuned sensitivity profiles: High (Geriatric) for fragile fall-risk residents, Balanced (Standard) for general hospital wards, and Low (Active) for mobile rehab patients.
1. Stage 2 Caretaker SOS Review Window: Central care station review window ($30\,\text{s}$) with presets: 15s (Urgent), 30s (Recommended), 45s (Extended), 60s (Manual Ward).
2. Wearable Speaker Alert Volume: Controls onboard ES8311 DAC gain ($90\%$) with presets: Mute, Soft (40%), Medium (70%), Loud (90%), Max (100%), and Test Speaker.
3. Stage 1 User Self-Cancel Window: Sets local on-wrist/pendant grace period ($15\,\text{s}$) allowing conscious residents to tap "I'M OK" or click BOOT.
4. Impact Peak Threshold: Deceleration impact cutoff ($3.50\,\text{G}$) differentiating genuine floor strikes from normal arm motion.
5. Freefall Weightlessness Threshold: Gravity-loss detection threshold ($0.50\,\text{G}$) during initial descent.
6. Consecutive Confirmation Hits: Debounce sample count ($2\,\text{Hits}$) filtering single-sample mechanical noise spikes.
5-Stage Kinematic Fall Detection & Telecare Escalation
A life-safety progression bridging deterministic edge physics calculations with multi-tiered cloud telephony.
// 50Hz Standard Telemetry Packet
{
"device_id": "FW-W-B4F960",
"role": "WATCH",
"name": "Paarvathy",
"state": "MONITORING",
"accel": 1.01,
"gyro_x": 0.4, "gyro_y": 0.3, "gyro_z": 0.3,
"bat": 79, "voltage": 4.01,
"rssi": -60, "ip": "192.168.1.59"
}
// Critical Emergency Fall Alert Packet
{
"event_id": "EVT-89234-F960",
"device_id": "FW-W-B4F960",
"name": "Paarvathy",
"phone": "+919944429848",
"room": "Ward-3B-Kailasha",
"state": "CRITICAL_SOS",
"peak_impact_g": 3.82,
"tilt_angle_deg": 74.2
}
Interactive Kinematic Oscillogram & Alarm Synthesizer
Test real-time 50Hz acceleration stream behavior, Resident Status Orb states, and synthesized audio sirens live in your browser.
Click the status orb to cycle clinical states: NORMAL (Green) โ VERIFYING (Amber 10s) โ CRITICAL SOS (Red).
Electrical Specifications & Power Budgeting
Operating boundaries, dynamic power consumption profiles, and institutional manufacturing standards.
| Parameter | Min | Typ | Max | Unit |
|---|---|---|---|---|
| Supply Voltage ($V_{\text{BUS}}$ USB-C) | 4.75 | 5.00 | 5.50 | V |
| Li-Po Battery Operating Voltage ($V_{\text{BAT}}$) | 3.30 | 3.80 | 4.25 | V |
| Active Operating Current (Screen ON, Wi-Fi TX, IMU 50Hz) | โ | 115 | 240 | mA |
| Audio Alarm Active Output Current (Peak SPL Output) | โ | 210 | 380 | mA |
| Low-Power Deep Sleep Current (Motion Wake Armed) | โ | 1.8 | 3.5 | mA |
| Display Luminance (Watch AMOLED / Pendant LCD) | โ | 600 | 1000 | cd/mยฒ |
โข Dual-Partition OTA Firmware Rollback: Both Watch and Pendant utilize a dual-partition OTA scheme with automatic rollback to previous verified image in case of checksum mismatch or watchdog timeout.
โข Offline Black-Box Flight Recording: In the event of Wi-Fi router disconnection or power failure, raw 50Hz kinematic samples are logged directly to the onboard MicroSD card.
โข Multi-Tier Cloud Failover: WebSockets replication to Supabase PostgreSQL paired with HiveMQ enterprise broker guarantees persistent emergency logging even during spotty connectivity.
Autonomous Geriatric Protection with FallNet Pro
By seamlessly unifying continuous 50Hz edge IMU sensor fusion on dual wearable form factors (Watch and Pendant) with a robust cloud telecare dashboard (https://care.inayat.net/), FallNet Pro drastically reduces emergency response latencies from hours to seconds while preventing false alarm fatigue.